HTPA - 014 Series For Plastics Fluorescent Colour


HTPA- 014 series pigments are improved version of HTPA series. They are solid solutions of Fluorescent Dyes in Thermoplastic resin for plastic coloring except PVC.

FEATURES

* Brighter and cleaner shades
* Easily dispersing / melting type pigments
* Imparts faster & easier dispersion in polymer
* Fine Particles


COLOUR RANGE

Color Code
Yellow 1014
Green 2014
Chrome 3014
Orange 4014
Red Orange 5014
Color Code
Red 6014
Pink 7014
Magenta 8014
Violet 9014
Blue 0114


CHARACTERISTICS

* Chemical Nature Thermoplastic polyester Resin
* Bulk Density 0.32 gm/cc
* Av. Particle Size 4-5 Microns
* Melting Point (M.P.) 100-1100C
* Thermal Stability < 2600C Max
* Decomposition Point 2800C
* Min Process Temp 1300C

# Typical Values
* Fluorescence maintained with minimal colour shift.


PROCESSING TEMPERATURE


HTPA - 014 series have avg. M.P. of 105oC and require minimum processing temperature of atleast 130oC and can be processed at temperature upto 280oC , with reasonable dwell time.

DISPERSION


To ensure complete dispersion and colour development with HTPA-014 Series - It is essential that a minimum processing temperature of 130oC with good shear action is required to ensure complete melting and even distribution.

ADDITIVES


Certain metal ions cause colour changes and loss of brightness. Addititves containing Zinc, Magnesium, Calcium, Iron will cause colour shifts. If it is a must for use, it should be thoroughly tested to ensure colour stability.

TOXICITY


Fluorescent Pigments are in accoradance with European EN-71 Part3, 1988

 

APPLICATIONS :
HTPA-014 can be successfully employed to colour the following :

POLYMER CLASS POLYMER GRADES  
POLYETHYLENES LDPE, HDPE HMHDPE, LLDPE etc.
POLYSTRENES GPPS, HIPS
POLYPROPYLENES ALL GRADES
Recommended

* Disclaimer : Fluorescent colours have enough light fastness for indoor applications and limited outdoor exposure. Our techincal information, advices, shades, recommendations are offered for your guidance without warranty. Our providing this data does not relieve you of the responsibility of carrying out your own tests and experiments prior to use, Therefore, we make NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If you use of our materials results in need of servicing, repair, or correction of equipment, defaults in end product, data or formulation you assume any costs thereof. If no event shall aron's total liability to you for all damages, losses, and causes of action, exceed the amount paid by you, if any, for procurementof our used meterial, (whether in contract, tort, including, but not limited to, negligence, or otherwise).